Pelatihan Safe Operation And Maintenance Of Switchgear

Pelatihan Safe Operation And Maintenance Of Switchgear
Pelatihan Safe Operation And Maintenance Of Switchgear. Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety.
This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.
ikuti juga : training electrical equiptment maintenance
TUJUAN
1.Selection of appropriate type and rating of circuit breakers and switchgear
2.Fundamentals of operation of switchgear
3.Switchgear components (CTs, VTs, relays, cable terminations)
4.Safe operational policies including safety rules and safety documents
5.Diagnostic tools and test equipment
6.Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations
MATERI
1. SWITCHGEAR – ORIGINS dan TYPES
Single line diagrams
Active and passive network components
Circuit breaker utilisation
Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
Fuse switches
HV fuses in combination with, and as alternative to circuit breakers
Auto-reclosers and auto-reclose operation
2. APPLICATION OF SWITCHGEAR
Principles of current interruption
Plain break circuit breakers
Bulk and small oil volume circuit breakers
Turbulator (explosion pot)
Operating mechanisms
Transfer earth circuit breakers
Air break and air blast switchgear
SF6 and Vacuum
Switchgear in association with disconnectors
Fixed and withdrawable designs Switchgear standards
Factors affecting switchgear selection
3. SPECIFICATION OF SWITCHGEAR
Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents Simple and complex protection systems
Switchgear ancillaries, measurement CTs, VTs, relays Cable terminations
Indoor and outdoor operation
Substation and switch room layouts and design
4. SHORT CIRCUIT TESTING
Symmetrical and asymmetrical breaking
Make and break operations
Understanding test oscillograms
5. SAFETY POLICIES
General safety precautions and the use of personal protective equipment
Principles of safety rules
Principles of personnel authorisation
Operative training for safe operation of switchgear
Isolation in a circuit breaker context
Safety documentation
Operational and safety locking, caution and danger notices
Safe working in a substation environment
Safety interlocks
Substation alarms
Individual study task and presentation -safety policies in my company and how they might be improved
6. OPERATION OF MODERN SWITCHGEAR
7. ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT
Principles of time and condition based asset management
Asset registers
Asset management systems
8. DIAGNOSTICS, TESTING AND MAINTENANCE
Switchgear inspection methodologies
Partial discharge measurement and survey
Timing tests
Thermovision
Mechanisms of deterioration
Principles of circuit breaker maintenance
Maintaining oil circuit breakers
Contact maintenance and contact wipe
Oil testing
Maintaining vacuum circuit breakers
Maintaining SF6 circuit breakers
SOPs and DINs
Switchgear defects and defect control systems
PESERTA
This course is designed for personnel responsible for maintenance, testing and troubleshooting low voltage power circuit breakers, protective relays, breaker trip devices and switchgear panels. The lab provides students with the opportunity to work on a variety of low voltage circuit breakers.
Telp/wa | |
---|---|
infodiklat.indonesia@gmail.com | 0852 9095 1223 |
Lokasi & Investasi | Fasilitas |
---|---|
- Yogyakarta - Jakarta - Bandung - Bali - Surabaya - Malang - Batam - Lombok | - FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara/Stasiun/Terminal) - FREE Transporsi Peserta ke tempat pelatihan . - Module atau Handout - FREE Flashdisk - Sertifikat - FREE Bag or bagpackers (Tas Training) - Training Kit (Dokumentasi photo, Blocknote, ATK, etc) - 2x Coffe Break & 1 Lunch - FREE Souvenir Exclusive - Training room full AC and Multimedia |
Catatan |
---|
Hotel untuk pelatihan ada beberapa pilihan seperti Hotel Ibis, Hotel Aston, Hotel Amaris, Hotel Cavinton, Hotel Hyatt, Hotel Grand Aston, Novotel, Hotel Harris, Hotel 101, Hotel Grand Mercure,Ritz Carlton, Hotel Ibis Style dan masih banyak pilihan menarik lainnya.Apabila perusahaan membutuhkan paket in house training anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan. Dapatkan harga spesial untuk pengiriman minimal 3 peserta dari perusahaan yang sama. |
Jadwal Pelatihan | Online Training |
---|---|
- 14-16 Januari 2025 - 4-6 Februari 2025 - 18-19 Msret 2025 - 22-24 April 2025 - 6-8 Mei 2025 - 17-19 Juni 2025 - 8-10 Juli & 29-31 JuIi 2025 - 26-28 Agustis 2025 - 16-18 September 2025 - 7-9 Oktober 2025 - 11-12 November 2025 - 2-4 Desember & 16-18 Desember 2025 | - Instruktur mengajar secara LIVE Durasi 4 jam perhari selama 2 hari pelaksanaan - Media Live training Google Meet, Zoom atau Team link - Harga khusus Training yang sama diikuti oleh beberapa peserta dari perusahaan yang sama |